Skip to content
Skip to product information
Description

Water Distiller Stainless Steel Glass Bucket Single Button with Power Switch 4L. Precision polishing stainless steel shell and high quality edible stainless steel liner. High hardness and large capacity glass watter bottle.  Anti-dry burning function. One button switch is easy to operate. 304 stainless steel water tray and barrel body. Head assembly handle, easy to handle. 304 stainless steel nozzle, surface fine polishing, clean and beautifu. Four aluminum fan blades, heat dissipation fast, enhance the service life of products. Aluminum condemsing tube, short cooling time, fast water outlet speed. Help you improve the quality of water.

Overview
  • K40101 is a Dental Medical Filter Purifier Distilled Purify Pure Dew.
  • Advanced silent fan + two disc super cooling technology : Steam super cooling.
  • ON/OFF switch : Start or stop condensate production at any time.
  • Anti-dry burning function :After the water inside the main engine is dried , the temperature control will auto automatic protect and turn off the power.
  • Rapid water production : 4L condensed water can be produced in 3.5 hours.
Product Introduction
    This item is suit for hospital, clinic, home, office, laboratory, travel and so on. Autoclave must adopt distilled water as operation medium.Even purified water has various minerals and can produce furring scale after evaporation at high temperature,which,after a period of time,can lead to leaking of steam due to improper  closure. It can also lead to the clog in the narrow pipes and pressure sensor,to the malfunction of temperature sensor and to other failures. Once the furring scale enters hand piece and axis. lowering the turning speed of hand piece,thus reading its life span. Therefore, using distilled water is necessary. But since all the clinics are located far from each other. It is difficult for them to buy distilled water. Now with this Water Distilled Machine Provided, you have a reliable source of high quality distilled water as long as you input pipe water!
Matters Needing Attention
  • Before using this product, please read this manual carefully and keep it properly for future reference.
  • Do not immerse the machine head and base in water or other liquids, and do not flush with a faucet.
  • After the water in the distillation drum is dried and the temperature control is automatically protected, open the head assembly after an interval of about 10 minutes to avoid possible scalding caused by steam in the drum.
  • Before the product is powered on, confirm whether the marked voltage is consistent with the local voltage.
    If the plug or socket or the product is damaged, it is not allowed to dismantle the machine for maintenance without permission, so as to avoid the wrong connection of internal lines, resulting in power on short circuit and other hazards.
  • This product is not suitable for children, people with incomplete limbs or mental disorders to avoid injury caused by wrong use.
  • When taking out the head assembly or cleaning the product, first turn off the on / off switch and unplug the power plug of the head assembly and the host.
  • When using for the first time, add 1.0L of water and 2 tablespoons of citric acid into the inner tank of the main engine, cover the head assembly, power on and boil water for about 20 minutes. After pouring out the water, rinse the inner tank and distillation cover with clean water (the distilled water produced for the first time cannot be drunk).
  • During internal cleaning, it is forbidden to use hard objects such as steel wire brush to brush the inner tank of the main engine and the inner tank of the machine head, so as to avoid the damage of the inner tank surface and the formation of scratches, resulting in the accumulation of dirt in the gap with fine scratches.
Instructions
  • Open the package, take out the whole machine, take out the machine head, and take out the accessories inside the liner
  • If it is a glass bottle, it is necessary to assemble the handle of the cup and ensure that the handle is firmly assembled
  • The inner tank of the main engine is added to the large scale water mark (it is forbidden to cross the water mark)
  • Place the machine head on the host (check whether the sealing ring of the machine head is installed properly or whether the sealing ring is missing), insert the link (three plug) power plug of the machine head into the host socket, and insert the host power line plug (three plug) into the host power socket.
  • After confirming that the plug is correctly connected and firmly inserted, insert the host power plug into the socket
  • Turn on the on / off switch on the back of the host, then press the start button, the start button indicator light is on, the fan on the head starts to work, and the host enters the heating state.
  • Align the water outlet of the water bottle with the water outlet of the main engine. When the main engine is heated for about 30 minutes, distilled water begins to drip slowly from the water outlet of the main engine until the water in the main engine tank is completely dried. The temperature control is automatically protected, and the power supply needs to be turned off.
  • When it is necessary to stop water making, you can turn off on / off without waiting for the water in the main engine tank to completely dry.
  • This product can continuously cool condensed water, that is, after the water in the inner tank is distilled, turn off the on / off switch, turn on the head assembly after an interval of about 10 minutes, add large-scale water into the inner tank of the main engine, and start the power supply again for operation and use, so as to cycle.
Cleaning
  • If the shell is soiled ,wipe it with a flexible cloth.
  • After each use of the main engine tank ,clean the residual fouling with clean water ,and at least burn the cleaning reagent (citric acid) recommended by our company every month.
  • Add 1.0L water and 2 tablespoons citric acid into the tank of the main engine , without covering the head component , boil water for about 30 minutes after electrifying ,then pour out the water and use it to clear rinse with water . If scale cannot be removed at one time , the above method can be repeated for cleaning.
  • If it is a plastic outlet ,it is recommended to replace it every 2 to 3 months.
Common Exceptions and Handing
  • No distilled water dripping
    1.The power supply of the host and the power socket of the machine head are not plugged into the socket .Please check and plug it again.
    2.Did not press the start button (the red indicator light did not go on) .
    3.No water is added to the main engine tank .
  • The amount of water distilled each time is not enough
    1.The water in the main engine tank does not reach the maximum water level scale.
    2.Leakage or poor sealing of the sealing ring of the nose assembly shall be checked , and the sealing ring shall be reassembled or replaced with a new one .
    3.No water is added to the tank of the main engine.
    4.The outlet nozzle of the machine head is not properly installed , which needs to be removed and reassembled .
  • The head assembly water boiling process shaking or water overflow
    1.The water in the main engine tank exceeds the scale line of the maximum water level.
    2.If the head component is not installed in place in conjunction with the host machine ,it shall be taken out and replaced on the host machine ,and the effect of placement shall be properly felt by hand .
    3.The sealing ring of the machine head component is not installed well , it needs to be taken out and reassembled.
    4.The outlet nozzle is clogged with dirt precipitation , and the outlet nozzle needs to be replaced or cleaned.
Specifications
Product Model:  K40201
Product Description:  SUS + single button
Rated Voltage:  220V / 120V
Rated Frequency:  50 / 60Hz
Rated Power:  750W
Capacity:  4L
Distilled Water Volume:  1L / h
Material:  SUS304 / 0.51mm
Outlet Nozzle:  SUS304
Shell:  SUS304
Control:  Single button with power switch
Bucket:  Glass bucket
Head Power Cord:  General / H03-VV F/ 0.5
Host Power Cord:  GS / 3C / UL / BS
Package List
Water distiller:  1
Power cord: 1
Water outlet:  1
Citric acid cleaner:  1
Active carbon:  1
Glass bottle:  1
Glass bottle handle:  1
Glass bottle fixed ring:  2
Screw:  1

4L Water Distiller Stainless Steel Glass Bucket Single Button with Power Switch
SKU:

1160400123

Regular price $187.52

Payment & Security
PayPal Visa Mastercard American Express Discover

The payment information on your card will be strictly protected. All transactions are secure and encrypted.

5% OFF for First Order. Coupon Code: NEW5%

6% OFF Over $500. (Auto Discount)

Free Shipping For Payments Amount Over $200(Shipping Time 5-15 days)

Accepts 60-day Returns and Refunds

Water Distiller Stainless Steel Glass Bucket Single Button with Power Switch 4L. Precision polishing stainless steel shell and high quality edible stainless steel liner. High hardness and large capacity glass watter bottle.  Anti-dry burning function. One button switch is easy to operate. 304 stainless steel water tray and barrel body. Head assembly handle, easy to handle. 304 stainless steel nozzle, surface fine polishing, clean and beautifu. Four aluminum fan blades, heat dissipation fast, enhance the service life of products. Aluminum condemsing tube, short cooling time, fast water outlet speed. Help you improve the quality of water.

Overview
  • K40101 is a Dental Medical Filter Purifier Distilled Purify Pure Dew.
  • Advanced silent fan + two disc super cooling technology : Steam super cooling.
  • ON/OFF switch : Start or stop condensate production at any time.
  • Anti-dry burning function :After the water inside the main engine is dried , the temperature control will auto automatic protect and turn off the power.
  • Rapid water production : 4L condensed water can be produced in 3.5 hours.
Product Introduction
    This item is suit for hospital, clinic, home, office, laboratory, travel and so on. Autoclave must adopt distilled water as operation medium.Even purified water has various minerals and can produce furring scale after evaporation at high temperature,which,after a period of time,can lead to leaking of steam due to improper  closure. It can also lead to the clog in the narrow pipes and pressure sensor,to the malfunction of temperature sensor and to other failures. Once the furring scale enters hand piece and axis. lowering the turning speed of hand piece,thus reading its life span. Therefore, using distilled water is necessary. But since all the clinics are located far from each other. It is difficult for them to buy distilled water. Now with this Water Distilled Machine Provided, you have a reliable source of high quality distilled water as long as you input pipe water!
Matters Needing Attention
  • Before using this product, please read this manual carefully and keep it properly for future reference.
  • Do not immerse the machine head and base in water or other liquids, and do not flush with a faucet.
  • After the water in the distillation drum is dried and the temperature control is automatically protected, open the head assembly after an interval of about 10 minutes to avoid possible scalding caused by steam in the drum.
  • Before the product is powered on, confirm whether the marked voltage is consistent with the local voltage.
    If the plug or socket or the product is damaged, it is not allowed to dismantle the machine for maintenance without permission, so as to avoid the wrong connection of internal lines, resulting in power on short circuit and other hazards.
  • This product is not suitable for children, people with incomplete limbs or mental disorders to avoid injury caused by wrong use.
  • When taking out the head assembly or cleaning the product, first turn off the on / off switch and unplug the power plug of the head assembly and the host.
  • When using for the first time, add 1.0L of water and 2 tablespoons of citric acid into the inner tank of the main engine, cover the head assembly, power on and boil water for about 20 minutes. After pouring out the water, rinse the inner tank and distillation cover with clean water (the distilled water produced for the first time cannot be drunk).
  • During internal cleaning, it is forbidden to use hard objects such as steel wire brush to brush the inner tank of the main engine and the inner tank of the machine head, so as to avoid the damage of the inner tank surface and the formation of scratches, resulting in the accumulation of dirt in the gap with fine scratches.
Instructions
  • Open the package, take out the whole machine, take out the machine head, and take out the accessories inside the liner
  • If it is a glass bottle, it is necessary to assemble the handle of the cup and ensure that the handle is firmly assembled
  • The inner tank of the main engine is added to the large scale water mark (it is forbidden to cross the water mark)
  • Place the machine head on the host (check whether the sealing ring of the machine head is installed properly or whether the sealing ring is missing), insert the link (three plug) power plug of the machine head into the host socket, and insert the host power line plug (three plug) into the host power socket.
  • After confirming that the plug is correctly connected and firmly inserted, insert the host power plug into the socket
  • Turn on the on / off switch on the back of the host, then press the start button, the start button indicator light is on, the fan on the head starts to work, and the host enters the heating state.
  • Align the water outlet of the water bottle with the water outlet of the main engine. When the main engine is heated for about 30 minutes, distilled water begins to drip slowly from the water outlet of the main engine until the water in the main engine tank is completely dried. The temperature control is automatically protected, and the power supply needs to be turned off.
  • When it is necessary to stop water making, you can turn off on / off without waiting for the water in the main engine tank to completely dry.
  • This product can continuously cool condensed water, that is, after the water in the inner tank is distilled, turn off the on / off switch, turn on the head assembly after an interval of about 10 minutes, add large-scale water into the inner tank of the main engine, and start the power supply again for operation and use, so as to cycle.
Cleaning
  • If the shell is soiled ,wipe it with a flexible cloth.
  • After each use of the main engine tank ,clean the residual fouling with clean water ,and at least burn the cleaning reagent (citric acid) recommended by our company every month.
  • Add 1.0L water and 2 tablespoons citric acid into the tank of the main engine , without covering the head component , boil water for about 30 minutes after electrifying ,then pour out the water and use it to clear rinse with water . If scale cannot be removed at one time , the above method can be repeated for cleaning.
  • If it is a plastic outlet ,it is recommended to replace it every 2 to 3 months.
Common Exceptions and Handing
  • No distilled water dripping
    1.The power supply of the host and the power socket of the machine head are not plugged into the socket .Please check and plug it again.
    2.Did not press the start button (the red indicator light did not go on) .
    3.No water is added to the main engine tank .
  • The amount of water distilled each time is not enough
    1.The water in the main engine tank does not reach the maximum water level scale.
    2.Leakage or poor sealing of the sealing ring of the nose assembly shall be checked , and the sealing ring shall be reassembled or replaced with a new one .
    3.No water is added to the tank of the main engine.
    4.The outlet nozzle of the machine head is not properly installed , which needs to be removed and reassembled .
  • The head assembly water boiling process shaking or water overflow
    1.The water in the main engine tank exceeds the scale line of the maximum water level.
    2.If the head component is not installed in place in conjunction with the host machine ,it shall be taken out and replaced on the host machine ,and the effect of placement shall be properly felt by hand .
    3.The sealing ring of the machine head component is not installed well , it needs to be taken out and reassembled.
    4.The outlet nozzle is clogged with dirt precipitation , and the outlet nozzle needs to be replaced or cleaned.
Specifications
Product Model:  K40201
Product Description:  SUS + single button
Rated Voltage:  220V / 120V
Rated Frequency:  50 / 60Hz
Rated Power:  750W
Capacity:  4L
Distilled Water Volume:  1L / h
Material:  SUS304 / 0.51mm
Outlet Nozzle:  SUS304
Shell:  SUS304
Control:  Single button with power switch
Bucket:  Glass bucket
Head Power Cord:  General / H03-VV F/ 0.5
Host Power Cord:  GS / 3C / UL / BS
Package List
Water distiller:  1
Power cord: 1
Water outlet:  1
Citric acid cleaner:  1
Active carbon:  1
Glass bottle:  1
Glass bottle handle:  1
Glass bottle fixed ring:  2
Screw:  1

4L Water Distiller Stainless Steel Glass Bucket Single Button with Power Switch - pairaydental.com
4L Water Distiller Stainless Steel Glass Bucket Single Button with Power Switch

Special Deals

View All >

Free shipping on orders over $200

payment amount under $200 have a $4.99 shipping fee. (Shipping Time in 5-15 days) Flat fee of $30 applies for Express Shipping.

60-day Returns & Money Back

We allow customers to apply for return or refund, exchange within 60 days after the receipt of the goods.

Top-notch support

Feel free to contact us on the phone, email or even live chat!

Secure payments

We accept PayPal, Visa, Master, American_express,Discover.

Drawer Title
Similar Products