Water Distiller Stainless Steel Plastic Bucket Double Screen Button with Adjustable Temperature 4L.
High quality plastic shell and stainless steel liner. With temperature display screen and temperature control button, you can adjust the temperature at will. Large capacity water bottle. 304 stainless steel water tray and barrel body. Head assembly handle, easy to handle. 304 stainless steel nozzle, surface fine polishing, clean and beautifu. Four aluminum fan blades, heat dissipation fast, enhance the service life of products. Aluminum condemsing tube, short cooling time, fast water outlet speed. Help you improve the quality of water.
- This distilled water machine can adjust the temperature.
- Advanced silent fan + two disc super cooling technology : Steam super cooling.
- ON/OFF switch : Start or stop condensate production at any time.
- Anti-dry burning function :After the water inside the main engine is dried , the temperature control will auto automatic protect and turn off the power.
- Rapid water production : 4L condensed water can be produced in 3.5 hours.
|
- This item is suit for hospital, clinic, home, office, laboratory, travel and so on. Autoclave must adopt distilled water as operation medium.Even purified water has various minerals and can produce furring scale after evaporation at high temperature,which,after a period of time,can lead to leaking of steam due to improper closure. It can also lead to the clog in the narrow pipes and pressure sensor,to the malfunction of temperature sensor and to other failures. Once the furring scale enters hand piece and axis. lowering the turning speed of hand piece,thus reading its life span. Therefore, using distilled water is necessary. But since all the clinics are located far from each other. It is difficult for them to buy distilled water. Now with this Water Distilled Machine Provided, you have a reliable source of high quality distilled water as long as you input pipe water!
|
Matters Needing Attention |
- Before using this product, please read this manual carefully and keep it properly for future reference.
- Do not immerse the machine head and base in water or other liquids, and do not flush with a faucet.
- After the water in the distillation drum is dried and the temperature control is automatically protected, open the head assembly after an interval of about 10 minutes to avoid possible scalding caused by steam in the drum.
- Before the product is powered on, confirm whether the marked voltage is consistent with the local voltage.
If the plug or socket or the product is damaged, it is not allowed to dismantle the machine for maintenance without permission, so as to avoid the wrong connection of internal lines, resulting in power on short circuit and other hazards.
- This product is not suitable for children, people with incomplete limbs or mental disorders to avoid injury caused by wrong use.
- When taking out the head assembly or cleaning the product, first turn off the on / off switch and unplug the power plug of the head assembly and the host.
- When using for the first time, add 1.0L of water and 2 tablespoons of citric acid into the inner tank of the main engine, cover the head assembly, power on and boil water for about 20 minutes. After pouring out the water, rinse the inner tank and distillation cover with clean water (the distilled water produced for the first time cannot be drunk).
- During internal cleaning, it is forbidden to use hard objects such as steel wire brush to brush the inner tank of the main engine and the inner tank of the machine head, so as to avoid the damage of the inner tank surface and the formation of scratches, resulting in the accumulation of dirt in the gap with fine scratches.
- When the production needs to be stopped, you can press the red on / off switch button under the host display screen, without waiting for the water in the host tank to completely dry.
|
- Open the package, take out the whole machine, take out the machine head, and take out the accessories inside the liner.
- If it is a glass bottle, it is necessary to assemble the handle of the cup and ensure that the handle is firmly assembled.
|
Steps for Preparing Distilled Water |
- The inner tank of the main engine is added to the large scale water mark (it is forbidden to cross the water mark).
- Place the machine head on the host (check whether the sealing ring of the machine head is installed properly or whether the sealing ring is missing), insert the link (three plug) power plug of the machine head into the host socket, and insert the host power line plug (three plug) into the host power socket.
- After confirming that the plug is correctly connected and firmly inserted, insert the host power plug into the socket, and both screens will display.
- Press the red on / off switch at the bottom left of the display screen, the left display screen displays the default temperature 105, the right display screen displays the current temperature, stop for 1 second, the head fan starts to work, the host enters the heating state, and the right display screen will change with the temperature change.
- Place the water outlet nozzle of the main engine at the mouth of the water bottle. When the main engine is heated for about 30 minutes, distilled water begins to drip slowly from the water outlet nozzle of the main engine until the water in the inner tank of the main engine is completely dried, the temperature control is automatically protected, and the display screen displays "E1". When the temperature drops down, the display screen lights up and displays, and then water can be added again for the next cycle.
|
- Put the steaming rack into the inner tank of the host and put the materials used for steaming wine on it.
- Place the machine head on the host (check whether the sealing ring of the machine head is installed properly or whether the sealing ring is missing), insert the connecting power plug (pin plug) of the machine head into the socket of the machine head, and insert the power cord plug (pin plug) of the machine head into the socket of the machine head.
- After confirming that the plug is correctly connected and firmly inserted, insert the host power plug into the wall socket, and will be displayed on both screens.
- Press the red on / off switch on the lower left side of the display screen, the left display screen displays the default temperature 105, and the right display screen displays the current temperature. At this time, according to the wine making demand, press the left and right buttons on the lower side of the display screen to adjust the wine making temperature of the left and right display screens (the low temperature can be set to 45 degrees Celsius, and the high temperature can be set to 108 degrees Celsius). After stopping for 1 second, the head fan starts to work, When the host enters the heating state, the right display screen will change with the change of temperature. After heating to the set temperature, that is, when the values of the left and right display screens are the same, it will enter the constant temperature state until the wine making is completed. Press the red on / off switch once and unplug the power plug.
|
- If the shell is soiled ,wipe it with a flexible cloth.
- After each use of the main engine tank ,clean the residual fouling with clean water ,and at least burn the cleaning reagent (citric acid) recommended by our company every month.
- Add 1.0L water and 2 tablespoons citric acid into the tank of the main engine , without covering the head component , boil water for about 30 minutes after electrifying ,then pour out the water and use it to clear rinse with water . If scale cannot be removed at one time , the above method can be repeated for cleaning.
- If it is a plastic outlet ,it is recommended to replace it every 2 to 3 months.
|
Common Exceptions and Handing |
-
No distilled water dripping
1.The power supply of the host and the power socket of the machine head are not plugged into the socket .Please check and plug it again. 2.Did not press the start button (the red indicator light did not go on) . 3.No water is added to the main engine tank .
-
There is not enough water for each distillation.
1. The water in the main engine tank does not reach the large water level mark. 2. If the sealing ring of the head assembly is missing or poorly sealed, check and reassembled the sealing ring or replace it with a new one. 3. There is no water in the main engine tank. 4. The water outlet nozzle of the machine head is poorly installed and needs to be removed and reassembled.
-
Shaking or water overflow during water boiling of head assembly.
1. The water in the main engine tank is too large, and the water level scale mark. 2. If the head assembly is not installed in place with the host, it needs to be taken out and placed on the host again, and feel the placement effect properly by hand. 3. The sealing ring of the head assembly is not installed properly, so it needs to be taken out and reassembled. 4. The outlet nozzle is blocked by dirt deposition, so it is necessary to replace the outlet nozzle or clean the outlet nozzle.
-
When the display shows "F"
The temperature sensor is not welded well or damaged, which needs to be repaired and replaced.
-
When the display shows "E1"
1. The temperature protection status will reset naturally. 2.If the machine always displays "E1", it needs to be repaired and replaced.
|
Product Model: |
K40105 |
Product Description: |
Plastic + Double screen button |
Rated Voltage: |
220V / 120V |
Rated Frequency: |
50 / 60Hz |
Rated Power: |
750W |
Capacity: |
4L |
Distilled Water Volume: |
1L / h |
Material: |
SUS304 / 0.51mm |
Outlet Nozzle: |
SUS304 |
Shell: |
Plastic shell |
Control: |
Double screen button with adjustable temperature |
Bucket: |
Plastic bucket |
Head Power Cord: |
General / H03-VV F/ 0.5 |
Host Power Cord: |
GS / 3C / UL / BS |
Water distiller: |
1
|
Power cord: |
1
|
Water outlet: |
1
|
Citric acid cleaner: |
1
|
Active carbon: |
1
|
Plastic bottle: |
1
|
Plastic bottle cover: |
1
|