Dental Wireless Electric Torque Driver Implant Torque Wrench with 16pcs Drivers 10-50Ncm 360° Rotating. 360° Precision Ratchet Head, Defined Tactile Stops at Every Angle. Equipped with a smart calibration system—alerts with a buzzer and stops automatically upon reaching preset torque. Seamlessly toggle directions with a single press, ensuring effortless control and smoother clinical workflows. Applications: Implant Installation & Removal, Abutment Placement, Healing Nut Adjustment. Professional Cordless Implant Wrench. A safe, high-efficiency solution for dental surgery.

Product manual download
Overview
  • One-Touch Forward/Reverse Switch: Seamlessly toggle directions with a single press, ensuring effortless control and smoother clinical workflows.
  • Comprehensive Implant & Repair Solutions: Perfect for first-phase implants, second-phase restorations, and versatile backup clinical tasks.
  • Precision Torque & Auto-Stop Control: Equipped with a smart calibration system—alerts with a buzzer and stops automatically upon reaching preset torque.
  • Applications: Implant Installation & Removal, Abutment Placement, Healing Nut Adjustment.
  • Sterilizable contra angle (Electronic handle can not be autoclaved)
Maintenance
  • Main Unit Care:
    If the tool will not be used for an extended period, recharge the battery every 15 days.
    Unplug the wrench motor main unit within 2 hours after it is fully charged. Failure to do so may damage the battery.
    After use, wipe the main-body housing with a soft cloth dampened with alcohol. Store it in a dry, well-ventilated area once the surface is completely dry.
    Important Note: Do NOT use highly concentrated ethanol or corrosive liquids to clean the main unit.
  • Maintenance of the bender:  
    Apply oil to the shaft center through the screw-start insertion port daily to extend shaft service life.
    Spray lubricant at the end of every workday for at least 1-2 seconds per application.
    For heavy-duty-workloads: Spray lubricant once at noon and again at the end of each workday.
    Spray lubricant before autoclaving.

Technical Specifications
Model: Electric Torque Driver XLY-DNBS300
Input Voltage: 100-240V/AC 50/60Hz
Output Voltage: DC 5V/1A
Battery model: INR 14500 3.7V 800mAh
Standard Head: 20:1
Rotation Speed: 10–50 r/min
Torque: 5–50 N·cm
Net Weight: 155g
Packing List
Main unit: 1
20:1 Contra Angle Handpiece Head: 1
Power Adapter: 1
Screwdrivers: 16
Certificate of Compliance: 1
Instruction manual: 1

Dental Wireless Electric Torque Driver Implant Torque Wrench with 16pcs Drivers 10-50Ncm 360° Rotating

SKU: 125040060
Low in stock (5)

Warehouse For US
3-5 business days for delivery.

Secure Delivery
Quantity: 1 Kit

$164.80

Payment & Security

  • American Express
  • JCB
  • Mastercard
  • PayPal
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Free Shipping For Payments Amount Over $200

5% OFF for First Order

Coupon Code: NEW5%

6% OFF Over $500 🌟 10% OFF Order Over $1200

 (Auto Discount)

Accepts 60-day Returns and Refunds

Dental Wireless Electric Torque Driver Implant Torque Wrench with 16pcs Drivers 10-50Ncm 360° Rotating. 360° Precision Ratchet Head, Defined Tactile Stops at Every Angle. Equipped with a smart calibration system—alerts with a buzzer and stops automatically upon reaching preset torque. Seamlessly toggle directions with a single press, ensuring effortless control and smoother clinical workflows. Applications: Implant Installation & Removal, Abutment Placement, Healing Nut Adjustment. Professional Cordless Implant Wrench. A safe, high-efficiency solution for dental surgery.

Product manual download
Overview
  • One-Touch Forward/Reverse Switch: Seamlessly toggle directions with a single press, ensuring effortless control and smoother clinical workflows.
  • Comprehensive Implant & Repair Solutions: Perfect for first-phase implants, second-phase restorations, and versatile backup clinical tasks.
  • Precision Torque & Auto-Stop Control: Equipped with a smart calibration system—alerts with a buzzer and stops automatically upon reaching preset torque.
  • Applications: Implant Installation & Removal, Abutment Placement, Healing Nut Adjustment.
  • Sterilizable contra angle (Electronic handle can not be autoclaved)
Maintenance
  • Main Unit Care:
    If the tool will not be used for an extended period, recharge the battery every 15 days.
    Unplug the wrench motor main unit within 2 hours after it is fully charged. Failure to do so may damage the battery.
    After use, wipe the main-body housing with a soft cloth dampened with alcohol. Store it in a dry, well-ventilated area once the surface is completely dry.
    Important Note: Do NOT use highly concentrated ethanol or corrosive liquids to clean the main unit.
  • Maintenance of the bender:  
    Apply oil to the shaft center through the screw-start insertion port daily to extend shaft service life.
    Spray lubricant at the end of every workday for at least 1-2 seconds per application.
    For heavy-duty-workloads: Spray lubricant once at noon and again at the end of each workday.
    Spray lubricant before autoclaving.

Technical Specifications
Model: Electric Torque Driver XLY-DNBS300
Input Voltage: 100-240V/AC 50/60Hz
Output Voltage: DC 5V/1A
Battery model: INR 14500 3.7V 800mAh
Standard Head: 20:1
Rotation Speed: 10–50 r/min
Torque: 5–50 N·cm
Net Weight: 155g
Packing List
Main unit: 1
20:1 Contra Angle Handpiece Head: 1
Power Adapter: 1
Screwdrivers: 16
Certificate of Compliance: 1