iRay Dental X-Ray Digital Intra-oral Sensor CMOS Detector Technology High Resolution Pluto 0001X. FDA approved. One year warranty. Pluto 0001X is digital size-1 intra-oral sensor. 20 μm pixel pitch CMOS sensor with CsI scintillator. Ergonomic design with smooth edges, rounded corners, and a flexible cable for maxi-mum patient comfort. Works with TWAIN supported software. TWAIN works well with Dexis.
Note: Direct integration software: iRay DR software, Dental Eye, Tigerview, Cadi.
Works with TWAIN supported software, our TWAIN works well with Dexis
The computer operating system adapted by our products is win7-win11
- CMOS detector technology
- Low dose clinical imaging
- High resolution
- Ensures optimal resolution with a 20 μm pixel pitch CMOS sensor and CSI scintillator.
- Wide dynamic range
- Pluto 0001X suitable for children and adults
- Slim, rounded corner and smooth edge
- Direct USB connectivity
- Easy to Use. Smart and Powerful Software. Waterproof. Durable.
- AED trigger, fast and easy workflow
- Durable material and components
- Friendly software user interface
- Works with TWAIN supported software. TWAIN works well with Dexis.
|
Model: |
Pluto 0001X |
Pluto 0015X |
Pluto 0002X |
Detector Technology: |
CMOS |
CMOS |
CMOS |
Scintillator: |
Direectly deposited CsI: TI |
Direectly deposited CsI: TI |
Direectly deposited CsI: TI |
Pixel Pitch (μm): |
20 |
20 |
20 |
Active Area (mm²): |
20 x 30 |
24 x 33 |
26 x 36 |
AD Conversion (bit): |
14 |
14 |
14 |
Exposure Mode: |
Smart AED |
Smart AED |
Smart AED |
X-ray Exposure Window (s): |
Max. 5s |
Max. 5s |
Max. 5s |
X-ray Energy Range (kV): |
55~100kV |
55~100kV |
55~100kV |
Data Interface: |
5G Wifi |
5G Wifi |
5G Wifi |
Power Dissipation (W): |
≤0.8W |
≤0.8W |
≤0.8W |
Dimensions (mm3): |
25.03 × 38.53 × 4.5 |
29.2 × 43.5 × 4.5 |
31.62 × 45.0 × 4.5 |
Length of cable(m): |
3m(Standard), 5m(Option) |
3m(Standard), 5m(Option) |
3m(Standard), 5m(Option) |
Housing material: |
Kevlar |
Kevlar |
Kevlar |
X-Ray shielding: |
Pb-shield behind active area |
Pb-shield behind active area |
Pb-shield behind active area |
Radiation dose: |
≥ 50Gy |
≥ 50Gy |
≥ 50Gy |
Ingress Protection: |
IP68 |
IP68 |
IP68 |
Operating Temperature (℃): |
10 ~ 40 |
10 ~ 40 |
10 ~ 40 |
Storage & Transport Temperature with Package (℃): |
-10~60 |
-10~60 |
-10~60 |
Operating Humidity (% RH): |
20 ~ 90 (Non-Condensing) |
20 ~ 90 (Non-Condensing) |
20 ~ 90 (Non-Condensing) |
Storage & Transport Humidity with Package (% RH): |
10 ~ 95 (Non-Condensing) |
10 ~ 95 (Non-Condensing) |
10 ~ 95 (Non-Condensing) |